Materials testing machines with torsion drives from 2 to 2000 Nm
TorsionLine testing machines with maintenance-free AC servo drives are designed for single-axis torsion tests under weight loading. The torque range is 20 Nm to 2,000 Nm. The torsion axis on the TorsionLine testing machine is positioned horizontally.
Description
Maximum stiffness ensures very accurate high rotation angle measurement resolution over the entire torque range, while high resolution allows excellent repeat accuracy to be achieved.
TorsionLine testing machines are equipped with an electrically interlocked safety device. Testing can only begin if the device is in the closed position.
testControl measurement and control electronics are used for torsion testing.
Principal areas of application for TorsionLine
Advantages & features
20 Nm/200 Nm/500 Nm
Type |
TL 020 |
TL 200 |
TL 500 |
|
|---|---|---|---|---|
Item No. |
1026875 |
1026878 |
1026879 |
|
Load frame |
||||
Torque (left/right) |
20 |
200 |
500 |
Nm |
Overall height with safety device |
1775 |
1775 |
1775 |
mm |
Overall width with safety cover |
1475 |
1475 |
1475 |
mm |
Overall depth |
650 |
650 |
650 |
mm |
Height of test axis |
adjustable |
adjustable |
adjustable |
|
Safety device |
electrically interlocked |
electrically interlocked |
electrically interlocked |
|
Torque transducer anti-rotation device |
manually operated, electrically monitored |
manually operated, electrically monitored |
manually operated, electrically monitored |
|
Weight with electronics, safety cover, torque transducer |
185 |
188 |
188 |
kg |
Grip-to-grip separation with 4-jaw chuck, max. |
510 |
510 |
510 |
mm |
Grip-to-grip separation with universal flanges (without specimen grips), max. |
680 |
680 |
680 |
mm |
Diameter of specimens/specimen holders, max. |
200 |
200 |
200 |
mm |
Finish |
RAL 7011 and RAL 7038 |
RAL 7011 and RAL 7038 |
RAL 7011 and RAL 7038 |
|
Ambient temperature |
+10 to +35 |
+10 to +35 |
+10 to +35 |
°C |
Relative humidity (non-condensing) |
20 to 90 |
20 to 90 |
20 to 90 |
% |
Noise level |
70 |
70 |
70 |
dB(A) |
Torsion inherent stiffness |
> 1000 |
> 1000 |
> 1000 |
Nm/° |
Axial frictional force during carriage travel (without torsion load), approx. |
4 |
4 |
4 |
N |
Drive |
||||
Rotational speed |
||||
in revolutions |
0.0005 to 180 |
0.0005 to 90 |
0.0005 to 50 |
r.p.m |
in degrees |
0.072 to 64800 |
0.036 to 32400 |
0.036 to 18000 |
°/min |
Angle resolution of drive |
3.29 |
1.89 |
0.92 |
arcsec/digit |
Positioning repeat accuracy (w/o reversal of direction) |
||||
at 1000 °/min |
≤20 |
≤10 |
≤10 |
arc-seconds |
Play at zero torque crossing |
< 1 |
< 1 |
< 1 |
arc-minutes |
Electrical supply data |
||||
Electrical power supply |
230 |
400 |
400 |
V, 1 Ph/N/PE |
Power consumption |
2.2 |
5 |
5 |
kVA |
Frequency |
50/60 |
50/60 |
50/60 |
Hz |
1000 Nm/2000 Nm
Type |
TL 1000 |
TL 2000 |
|
|---|---|---|---|
Item No. |
1026880 |
1026881 |
|
Load frame |
|||
Torque (left/right) |
1000 |
2000 |
Nm |
Dimensions |
|||
Height with safety device |
1430 |
mm |
|
Wide machine base |
2350 |
mm |
|
Width with protective cover |
2358 |
mm |
|
Depth |
860 |
mm |
|
Height of test axis, from the floor |
935 |
mm |
|
Safety device |
Electrically interlocked |
electrically interlocked |
|
Weight with electronics, safety cover, torque transducer |
1500 |
1400 |
kg |
Grip-to-grip separation with face-plate, without specimen holder, max. |
1000 |
mm |
|
Diameter of specimens/specimen holders, max. |
600 |
600 |
mm |
Finish |
RAL 7011 und RAL 7038 |
RAL 7011 and RAL 7038 |
|
Ambient temperature |
+10 to +35 |
+10 to +35 |
°C |
Relative humidity (non-condensing) |
20 to 90 |
20 to 90 |
% |
Noise level |
62 |
62 |
dB(A) |
Torsion inherent stiffness L = 1000 mm (without torque transducer), approx |
> 11,500 |
Nm/° |
|
Dimensions |
|||
Height with safety device |
|||
Wide machine base |
|||
Width with protective cover |
|||
Depth |
|||
Height of test axis, from the floor |
|||
Grip-to-grip separation with face-plate, without specimen holder, max. |
|||
Torsion inherent stiffness L = 1000 mm (without torque transducer), approx |
|||
Specimen holders |
|||
Connection to load frame (gearing, torque transducer) via the face plate: |
|||
Diameter of specimen mounting flange |
400 |
mm |
|
Connection to load frame (gearing, torque transducer) via the face plate: |
|||
Diameter of specimen mounting flange |
|||
Drive |
|||
Rotation speed |
|||
In turns |
0.0005 to 20 |
r.p.m |
|
In degrees |
0.18 to 7200 |
°/min |
|
Angle resolution of the drive |
0.5 |
Rotational second/minute |
|
Positioning repeat accuracy (without reversal of direction) |
|||
at 1,000 °/min |
≤5 |
Rotational second |
|
Play at zero torque crossing |
<5 |
< 5 |
Rotational minutes |
Rotation speed |
|||
In turns |
|||
In degrees |
|||
Angle resolution of the drive |
|||
Positioning repeat accuracy (without reversal of direction) |
|||
at 1,000 °/min |
|||
Connected loads |
|||
Electrical connection |
400 |
V, 3 Ph/N/PE |
|
Power consumption |
5 |
kVA |
|
Frequency |
50/60 |
Hz |
|
Electrical connection |
|||
Electrical supply data |
|||
Power consumption |
5 |
kVA |
|
Frequency |
50/60 |
Hz |
|